DC Buyer's Guide

TEAAC Frames 366AT to L508AT

Totally Enclosed Air-To-Air Cooled

Type CD

DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction

Motor Pricing General Information

Other Information Application Information Outline Dimensions Accessories and Modifications

Cooler Weight in Lb.

Cooler Type

Frame

XA

XB

XC

XD XE

XF

XG

XH

XJ

XK

XL

XM XN XW XY

XZ

CD366AT CD368AT CD407AT

Z Z A A A A A A A A A A B B B B B B

230 20.24 10.12 31.44 33.70 27.30 6.29 252 20.24 10.12 34.44 33.70 27.30 6.29 425 24.00 12.00 37.88 36.96 29.65 6.88 425 24.00 12.00 37.88 36.96 29.65 6.88 440 24.00 12.00 42.38 36.96 29.65 6.88 440 24.00 12.00 42.38 36.96 29.65 6.88 425 24.00 12.00 37.88 41.06 33.75 8.75 430 24.00 12.00 39.62 41.06 33.75 8.75 435 24.00 12.00 41.88 41.06 33.75 8.75 445 24.00 12.00 43.62 41.06 33.75 8.75 460 24.00 12.00 46.88 41.06 33.75 8.75 470 24.00 12.00 48.62 41.06 33.75 8.75 610 30.62 15.31 43.50 47.88 38.50 8.53 610 30.62 15.31 43.50 47.88 38.50 8.53 610 30.62 15.31 43.50 47.88 38.50 8.53 625 30.62 15.31 45.25 47.88 38.50 8.53 660 30.62 15.31 48.50 47.88 38.50 8.53 675 30.62 15.31 50.25 47.88 38.50 8.53

0.88 12.92 11.70 3.44 0.88 12.92 11.70 3.44 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50

6.60 6.60 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 8.75 8.75 8.75 8.75 8.75 8.75

2.5 2.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5

1.25 8.740 18.75 10.38 1.25 8.740 18.75 10.38 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50

L407AT

CD409AT

L409AT

CD504AT

L504AT

CD506AT

L506AT

CD508AT

L508AT

CD504AT

L504AT

CD506AT

L506AT

CD508AT

L508AT

Standard location of cooler conduit box is on the same side as machine conduit box, however, box will be located on opposite side if specified. Providing mounting conditions permit, conduit box may be turned so that entrance can be made upward, downward, or horizontally.

4.21

www.wolongamerica.com

GEP387-EN 07/19 Prices and data subject to change without notice.