DC Buyer's Guide
TEAAC Frames 366AT to L508AT
Totally Enclosed Air-To-Air Cooled
Type CD
DIMENSIONS - For ESTIMATING ONLY unless endorsed for construction
Motor Pricing General Information
Other Information Application Information Outline Dimensions Accessories and Modifications
Cooler Weight in Lb.
Cooler Type
Frame
XA
XB
XC
XD XE
XF
XG
XH
XJ
XK
XL
XM XN XW XY
XZ
CD366AT CD368AT CD407AT
Z Z A A A A A A A A A A B B B B B B
230 20.24 10.12 31.44 33.70 27.30 6.29 252 20.24 10.12 34.44 33.70 27.30 6.29 425 24.00 12.00 37.88 36.96 29.65 6.88 425 24.00 12.00 37.88 36.96 29.65 6.88 440 24.00 12.00 42.38 36.96 29.65 6.88 440 24.00 12.00 42.38 36.96 29.65 6.88 425 24.00 12.00 37.88 41.06 33.75 8.75 430 24.00 12.00 39.62 41.06 33.75 8.75 435 24.00 12.00 41.88 41.06 33.75 8.75 445 24.00 12.00 43.62 41.06 33.75 8.75 460 24.00 12.00 46.88 41.06 33.75 8.75 470 24.00 12.00 48.62 41.06 33.75 8.75 610 30.62 15.31 43.50 47.88 38.50 8.53 610 30.62 15.31 43.50 47.88 38.50 8.53 610 30.62 15.31 43.50 47.88 38.50 8.53 625 30.62 15.31 45.25 47.88 38.50 8.53 660 30.62 15.31 48.50 47.88 38.50 8.53 675 30.62 15.31 50.25 47.88 38.50 8.53
0.88 12.92 11.70 3.44 0.88 12.92 11.70 3.44 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.00 15.88 13.75 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50 1.18 19.12 17.19 5.50
6.60 6.60 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 7.62 8.75 8.75 8.75 8.75 8.75 8.75
2.5 2.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5
1.25 8.740 18.75 10.38 1.25 8.740 18.75 10.38 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 11.00 12.00 11.00 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50 1.25 13.25 15.00 13.50
L407AT
CD409AT
L409AT
CD504AT
L504AT
CD506AT
L506AT
CD508AT
L508AT
CD504AT
L504AT
CD506AT
L506AT
CD508AT
L508AT
Standard location of cooler conduit box is on the same side as machine conduit box, however, box will be located on opposite side if specified. Providing mounting conditions permit, conduit box may be turned so that entrance can be made upward, downward, or horizontally.
4.21
www.wolongamerica.com
GEP387-EN 07/19 Prices and data subject to change without notice.
Made with FlippingBook Digital Publishing Software