DC Buyer's Guide
Application Information
Air Flow Requirements for Separately Ventilated Motors
STATIC PRESSURE INCHES OF WATER A B C Standard
Static Pressure Inches of Water
Base Speed RPM CFM
Base Speed RPM 3500 2500 1750* 3500 2500 1750* 3500 2500 1750* 3500 2500 1750*
Enclosed Separately Ventilated
Frame
HP
Separately Ventilated
Blown From Drive End
CD6000
ALL
ALL
2400
3
Frame
CFM
Motor Pricing General Information
CD6100
ALL
ALL
3400
3
70 50 35
1.0 .6 .3 1.6 .8 .4 1.8 .86 .45
1.0 .6 .3
N/A N/A N/A
CD180AT
CD6200
ALL
ALL
4000
5
CD6700
ALL
ALL
5000
5
180 130 90 320 230 160 540 385 270
2.96 1.5 .74 3.28 1.66 .82 3.92 1.96 .98
3.7 1.9 .9 4.0 2.0 1.0 4.3 2.4 1.2
≤1500 >1500 ≤2000 >2000
ALL ALL ALL ALL
6200 8000
5 8
CD210AT
CD6800
CD6900 5 9 NOTE : Airflows are for clean dry air less than 40°C (104°F) and at altitudes less than 1000 M (3330 FT). 7500 10000
CD250AT
2.16 1.04 .54
CD280AT
WARNING : The static pressure values listed in the tabulations are based upon standard air inlet and standard air outlet utilization. The static pressure will be higher if either the air inlet or outlet openings are restricted in size or, in the case of air outlets, reduced in number.
CD320AT
ALL
650
2.0
3.2
3.0
CD360AT
ALL
610
2.2
3.9
3.4
CD400AT
ALL
830
2.6
3.65
4.0
CD504AT CD5010AY
ALL
1425
3.0
4.1
3.8
*1750 RPM or lower A. Standard Separately Ventilated Air in one CE opening with solid covers on other CE openings. Standard louvered covers on DE air outlets. B. Enclosed Separately Ventilated (Air ducted in an air ducted out) Air in one CE opening with solid covers on other CE opening. Air out one DE opening. C. Blown From Drive End Air in one DE opening with solid covers on other DE openings. Standard louvered covers on CE air outlets.
Other Information Application Information Outline Dimensions Accessories and Modifications
CD5010AY and Below
CD6000 and Above
ESV
SV
ESV
SV
Standard Air Inlet Location
CE TOP
CE TOP
DE*
DE*
DE (either side)
DE Side and Bottom
Standard Air Exit Location
CE*
CE**
CE - Commutator End
ESV - Enclosed Separately Ventilated
DE - Drive End
SV - Separately Ventilated
*Motors are shipped with solid covers on both sides and top and bottom. Any DE cover may be removed for air entry and any CE cover for air exit. If a transparent cover is ordered, it will be located on the CE, conduit box side. **If a transparent cover is ordered, air exit is opposite conduit box side and bottom. If not transparent cover is ordered, air is exited on both sides.
5.13
www.wolongamerica.com
GEP387-EN 07/19 Prices and data subject to change without notice.
Made with FlippingBook Digital Publishing Software