Standard Motor Catalog
Section MV High Power Motors
Keyless Shaft Motors for use on Reciprocating Compressors TEFC with Anti-friction Bearings Dimensions
AB
C
XN
XL
AA
V
O
45 O
ø U
D
N-W
K
J
øH
G
F
F
BA
E
E
A
2XF
B
TEFC
Dimensions in Inches
Keyless Shaft
Mounting
N-W U 1
A B C G
J
K O
Frame Poles
V 2
BA D 3
E 2F 2XF H
445TZ 447TZ 449TZ
4 8.50 3.375 8.25 7.50 11.00 9.00 16.50 14.50 0.81 20.00 18.80 45.62 1.49 2.64 4.96 23.94 4 8.50 3.375 8.25 7.50 11.00 9.00 25.00 20.00 0.81 20.00 27.31 54.12 1.49 2.64 8.81 23.94 4 8.50 3.375 8.25 7.50 11.00 9.00 25.00 20.00 0.81 20.00 27.31 54.12 1.49 2.64 8.81 23.94 4 8.50 3.375 8.25 7.50 11.00 9.00 25.00 – 0.81 20.24 27.31 59.37 1.49 2.70 5.26 24.04 4 8.50 4.500 8.00 8.50 12.50 10.00 28.00 25.00 1.07 23.00 31.90 68.88 1.35 7.09 8.36 30.80 4 8.50 4.500 8.00 8.50 12.50 10.00 36.00 32.00 1.07 23.00 39.90 76.88 1.35 7.09 10.00 30.80
449TZ (HO)
509Z
5011Z
Conduit Box Dimensions
ABOVE NEMA AC HORIZONTAL MOTORS
Dimensions in Inches
Frame Volume cu-in
AA
AB
XL
XN
445TZ 447TZ 449TZ
1260 1260 2500 5700 5700
(2) 4" - 8 NPT 22.60 (2) 4" - 8 NPT 22.60 (2) 4" - 8 NPT 23.26 (3) 3" - 8 NPT 28.83 (3) 3" - 8 NPT 28.83 (3) 4" - 8 NPT 34.57
12.35 12.35 13.73 22.25 22.25 25.00
16.25 16.25 27.24 22.25 22.25 41.00
509Z
5011Z
11500
Notes: 1 Tolerance on “U” dimension will be +0.000 inch, -0.001 inch 2 Dimension “V” represents length of straight part of shaft extension 3 Tolerance on “D” dimension will be +0.000 inch, -0.060 inch
Motors are depicted with representative conduit box. For specific dimensions or a complete motor outline drawing, contact your Wolong America representative.
MV.48
Data subject to change without notice. 10/24 • www.wolongamerica.com
Made with FlippingBook. PDF to flipbook with ease