Standard Motor Catalog

Section MV High Power Motors

Keyless Shaft Motors for use on Reciprocating Compressors WPII with Sleeve Bearings Dimensions

C

AB

AC

LIFTING LUGS FOR TOP COVER ONLY

I

ACCESS COVER – BOTH ENDS (TO FILTERS)

AIR DIFFERENTIAL PRESSURE SWITCH

REMOVABLE SCREENS AIR INLET (BOTH ENDS)

I

REMOVABLE SCREENS AIR OUTLET (BOTH ENDS) I 1

0

(4) LIFTING LUGS

N-W

V

0

0

XL

·-·-·-·-i-·-·-·

–-–-–-–- Ø U

D

G

I

I

J

Ø AA

E

E

XN

BA

Ø H

GROUNDING TERMINAL FOR AWG # 1/0–2/0 CABLES

A

F

F

B

WPII

Dimensions in Inches

Keyless Shaft

Mounting

N-W U 1

A B C G

J

O

Frame 5810Z

Poles

V 2

BA D 3

E F H

6 8.00 5.0 7.75 10.00 14.50 11.50 18.00 1.18 30.40 54.00 80.50 1.64 5.52 62.00 6 8.00 5.0 7.75 16.00 14.50 11.50 22.50 1.18 30.40 67.00 93.50 1.64 5.52 62.00 8 8.00 5.0 7.75 16.00 14.50 11.50 22.50 1.18 30.40 67.00 93.50 1.64 5.52 62.00 6 8.75 6.0 8.50 11.50 17.00 13.50 25.00 1.18 34.00 61.00 82.70 2.25 5.50 90.69 6 9.75 6.0 9.50 14.00 17.00 13.50 31.50 1.18 34.00 74.00 96.50 2.25 5.50 90.69 8 9.75 6.0 9.50 14.00 17.00 13.50 31.50 1.18 34.00 74.00 96.50 2.25 5.50 90.69 6 9.75 6.5 9.50 14.00 17.00 13.50 31.50 1.18 34.00 74.00 96.50 2.25 5.50 90.69 6 12.25 7.5 12.00 14.00 20.00 17.00 28.00 1.44 40.00 68.00 96.10 1.25 5.00 82.19 8 12.25 6.5 12.00 14.00 20.00 17.00 32.00 1.44 40.00 68.00 96.10 1.25 5.00 82.19 6 12.25 7.5 12.00 14.00 20.00 17.00 35.50 1.44 40.00 75.00 103.10 1.25 5.00 82.19 8 12.75 7.5 12.50 16.00 24.00 21.50 31.50 1.56 48.00 77.00 107.20 1.25 5.00 98.59 8 12.75 7.5 12.50 16.00 24.00 21.50 35.50 1.56 48.00 85.00 115.20 1.25 5.00 98.59

5812Z

6811Z

6813Z

8010Z 8011Z 8012Z 9611Z 9612Z

ABOVE NEMA AC HORIZONTAL MOTORS

Conduit Box Dimensions

Dimensions in Inches

Frame 5800Z 6800Z 8000Z 9600Z

Volume cu-in

AA

AB

AC

XL

XN

5700 5700 5700 5700

4" - 8 NPT 4" - 8 NPT 4" - 8 NPT 4" - 8 NPT

44.81 52.50 56.50 65.50

37.44 43.75 47.75 52.75

27.72 27.72 27.72 27.72

28.74 28.74 28.74 28.74

Notes: All 6800+ frame motors are Wolong branded.

1 Tolerance on “U” dimension will be +0.000 inch, -0.001 inch 2 Dimension “V” represents length of straight part of shaft extension 3 Tolerance on “D” dimension will be +0.000 inch, -0.060 inch

Motors are depicted with representative conduit box. For specific dimensions or a complete motor outline drawing, contact your Wolong America representative.

MV.51

Data subject to change without notice. 10/24 • www.wolongamerica.com