Standard Motor Catalog

Section XS XSD Ultra NEMA Premium Extra Severe Duty Motors Adjustable Speed Motors ASD Ultra ® Dimensions (cont.)

Conduit Box Dimensions

Frame

Normal HP (40)

Approx. Volume

AA

AB

AC (23)

AF

XL

XN

182T-184T 213T-215T 254T-256T 284T-286T 324T-326T 364T-365T 404T-405T 444T-449T

5

32 32 76

0.75 1.00 1.25 1.50 3.00 3.00 3.00 4.00

7.83 9.50

6.32 7.42 9.12 9.88

2.50 3.50 4.59 4.59 6.44 6.44 7.00 7.00

4.30 5.78 7.38 7.38

5.40 4.16 5.38 5.38 7.00 7.00

10 20 30 50 75

12.15 12.91 16.13 17.13 20.54 22.06

137 346 346 700

12.43 13.43 16.28 17.80

10.12 10.12 12.13 12.35

100 300

10.50 16.25

1260

Notes: 23 Insulated ODE bearing and shaft ground brush on DE 40 Conduit box size is determined by full load amps. Nominal horsepower is stated as a reference only. Providing mounting conditions permit, conduit box may be turned so that entrance can be made upward, downward or from either side.

Blower Dimensions

Frame

YA

YB

YE

YH

364T-365T 404T-405T 444T-449T

25.22 27.58 33.95

13.54 13.54 20.08

3.57 2.84 2.44

0.875 0.875 1.094

C-Face Mounting

All Dimensions in Inches

NEMA Frame 143TC-145TC 182TC-184TC 213TC-215TC 254TC-256TC 284TC-286TC

AH

AJ

AK

U

Key Width Key Thickness Key Length

2.12 2.62 3.12 3.75 4.38

5.88 7.25 7.25 7.25 9.00

4.50 8.50 8.50 8.50

0.875 1.125 1.375 1.625 1.875

0.19 0.25 0.31 0.38 0.50

0.19 0.25 0.31 0.38 0.50

1.38 1.75 2.38 2.88 3.25

10.50

XS.38

Data subject to change without notice. 12/23 • www.wolongamerica.com