StandardMotorCatalog

Section MV High Power Motors Quantum ™ LMV—TEFC Dimensions

Dimensions refer to drawings on following page

Frame 500, Totally Enclosed Fan Cooled

Shaft

Mounting

Keyway

Key Length N-W U 1

Frame E H BA 2F 2XF 508L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 – 25.00 23.00 31.90 72.39 12.50 1.35 7.09 8.36 37.88 30.80 30.45 508LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 – 25.00 23.00 31.90 67.14 12.50 1.35 7.09 8.36 37.88 30.80 30.45 508LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 – 25.00 23.00 31.90 66.14 12.50 1.35 7.09 8.36 37.88 30.80 30.45 509L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 28.00 – 23.00 31.90 72.39 12.50 1.35 7.09 8.36 37.88 30.80 30.45 509LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 28.00 – 23.00 31.90 67.14 12.50 1.35 7.09 8.36 37.88 30.80 30.45 509LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 28.00 – 23.00 31.90 66.14 12.50 1.35 7.09 8.36 37.88 30.80 30.45 5010L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 – 32.00 23.00 39.90 80.39 12.50 1.35 7.09 10.00 41.88 30.80 30.45 5010LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 – 32.00 23.00 39.90 75.14 12.50 1.35 7.09 10.00 41.88 30.80 30.45 5010LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 – 32.00 23.00 39.90 74.14 12.50 1.35 7.09 10.00 41.88 30.80 30.45 5011L 1.000 0.500 10.00 12.00 3.875 11.50 10.00 1.07 8.50 36.00 – 23.00 39.90 80.39 12.50 1.35 7.09 10.00 41.88 30.80 30.45 5011LL 0.875 0.437 5.00 6.75 3.375 6.50 10.00 1.07 8.50 36.00 – 23.00 39.90 75.14 12.50 1.35 7.09 10.00 41.88 30.80 30.45 5011LS 0.625 0.312 4.00 5.75 2.625 5.50 10.00 1.07 8.50 36.00 – 23.00 39.90 74.14 12.50 1.35 7.09 10.00 41.88 30.80 30.45 5012S 1.000 0.500 5.50 7.75 3.875 7.50 10.00 1.07 8.50 – 40.00 23.00 48.90 85.14 12.50 1.35 7.09 10.00 46.38 30.80 30.45 5012ST 0.750 0.375 4.00 5.75 2.875 5.50 10.00 1.07 8.50 – 40.00 23.00 48.90 83.13 12.50 1.35 7.09 10.00 46.38 30.80 30.45 5013S 1.000 0.500 5.50 7.75 3.875 7.50 10.00 1.07 8.50 45.00 – 23.00 48.90 85.14 12.50 1.35 7.09 10.00 46.38 30.80 30.45 5013ST 0.750 0.375 4.00 5.75 2.875 5.50 10.00 1.07 8.50 45.00 – 23.00 48.90 83.13 12.50 1.35 7.09 10.00 46.38 30.80 30.45 A B C D 3 G J K L O P V 2 Width Depth

Conduit Box Dimensions

Approx. Volume

Max. FL Amps 4

AA

AB

XL

XN

R

Frame

400 600

1260 2500 5700

2-4.00 2-4.00 3-3.00

22.67 22.98 28.83

12.39 14.50 22.25

16.25 23.95 22.25

35.14 35.63 41.30

508-5013

1200

Notes: 1

Tolerance on “U” dimension will be +0.000 inch - 0.001 Dimension “V” represents length of straight part of shaft extension Tolerance on “D” dimension will be + 0.000 inch - 0.060 inch

2 3 4

Conduit box size is determined by full load amps

Providing mounting conditions permit, conduit box may be turned so that entrance can be made upward, downward or from either side

MV.17

Data subject to change without notice. 07/23 • www.gemotorswolong.com