Standard Motor Catalog
Section MV High Power Motors
Quantum ™ LMV—TEFC Severe Duty Medium Voltage with IEEE 841 Features Standard Features
HP Range
200 - 500
Poles
2, 4, 6
Voltage Altitude Ambient
2300/4000
3300 ft
40°C to -25°C NEMA Grade B
Balance/Vibration
Bearing Caps
Both Ends
Bearing Protection Bearing Temp Device
IP55; Non-contact rotating labyrinth seal on both ends
100 Ohm Platinum RTD both bearings
Bearing Type Conduit Box
Single Shielded Ball; 509L & 5011L have DE roller bearing Fabricated Steel; Gasketed and rotatable in 90 degree increments
Div 2 Temp Codes
CSA Certified Class I Div 2 Groups A, B, C, D T3 200C AIT at 1.0 SF (unless otherwise noted on pricing pages)
Drains
Stainless Steel T-drains in lowest section of both endshields Meets or exceeds IEEE 841-2009 efficiency requirements
Efficiency Enclosure End Shield
TEFC
Cast Iron
Fan
Bronze (Unidirectional on 2 poles)
Fan Cover Fasteners
Fabricated Steel SAE Grade 5 +/- 1.5 degrees
Foot Draft Angle Frame Material
Cast Iron 509-5013
Frame Size Frequency
60 Hz
Ground
Ground in conduit box and 2 NEMA Type ground pads on frame
Insulation Class Insulation System Inverter Capabilities
Class F
Epoxy VPI
Consult Factory
Bearing L10 Life
Belted - 26,280 hrs; Direct Coupled - 100,000 hrs
Leads
Permanently numbered, Non-wicking
Lifting Means
Two (2) cast in lifting lugs
ABOVE NEMA AC HORIZONTAL MOTORS Lubrication Polyurea Grease
Mounting
Foot mounted F1 only, contact factory for F2 mounting options Dual drilled for 508/509, 5010/5011, 5012/5013 mounting
Mounting Holes
Nameplate
316 Stainless Steel Standard Torque
NEMA Design Oil Mist Lube
Includes provisions for conversion to Oil Mist Lubrication
Paint
Epoxyester Buff, meets IEEE 841
Relubrication
Yes, both ends; extended through the fan cover
Rotor
Cast Aluminum
Service Factor Shaft Material Space Heater
1.15 (unless otherwise noted on pricing pages)
AISI 1045; 509L and 5011L AISI 4142
115V thermostatically controlled, leads to accessory box 100 Ohm Platinum stator winding RTD’s, leads to accessory box 80°C @ 1.0 SF (unless otherwise noted on pricing pages)
Stator Temp Device Temperature Rise
Tests
NEMA Routine Report including vibration supplied with motor, IEEE 112 Method B
Time Rating
Continuous
Vibration Pads
Cast in vibration pads for repeatable measurements
Warranty
60 months from date of installation or 66 months from date of manufacture, whichever occurs first
MV.16
Data subject to change without notice. 10/24 • www.wolongamerica.com
Made with FlippingBook. PDF to flipbook with ease